K85 is a PEMF red light near-infrared heating mini pad using nano-tourmaline micro-ceramic balls. The product combines adjustable heating, dual-coil PEMF and dual-band photonic lamps in a portable-sized pad, suitable for home relaxation, localized heating experiences, spas, health care stores and wellness spaces.

What is the K85 Multifunctional Heating Mini Pad?

K85 adopts a compact pad body design, with product dimensions of approximately 19 × 34 inches, equivalent to approximately 47 × 85 cm. Compared to full-size tourmaline pads, the K85 is easier to place, carry, and store, and can be used for daily rest and warmth on the back, waist, or under the legs.

The

product uses nano-tourmaline micro-ceramic balls inside and is equipped with thermal, PEMF and photon lamp bead modules. The warming system provides an adjustable hot compress experience; the PEMF module generates pulsed electromagnetic fields through 2 coils; the photonic module uses 660 nanometer red light and 850 nanometer near-infrared lamp beads.

Why choose K85?

  • Portable mini size: The pad size is approximately 47 × 85 cm, suitable for families, small nursing spaces and usage scenarios that require flexible placement.
  • Tourmaline micro-ceramic balls: uses nano-tourmaline micro-ceramic balls as the internal material to form a heating pad with the characteristics of mineral materials.
  • Dual Coil PEMF: has 2 built-in PEMF coils with frequency setting range from 3 to 64 Hz.
  • Dual-band photon lamp beads: is configured with 22 660 nm visible red light lamp beads and 14 850 nm invisible near-infrared lamp beads.
  • Adjustable temperature: Temperature range is 30 to 70 degrees Celsius, which is 85 to 159 degrees Fahrenheit.
  • Timing control: supports timing from 1 to 12 hours, and the running time can be set according to different usage scenarios.
  • Easy to store: product comes with a portable storage bag, suitable for home storage, store movement and sample display.
How does the PEMF configuration of

K85 work?

K85 has 2 built-in PEMF coils with frequency setting range from 3 to 64 Hz. Two coils are distributed in the main use area of ​​​​the pad body, and a pulsed electromagnetic field is generated through the controller. PEMF, thermal and photon lamp beads belong to different modules, and the specific operation methods should be carried out according to the product controller and instructions.

When evaluating the PEMF mini pad, purchasers can check whether the product configuration meets the brand project requirements by combining the frequency range, coil quantity, coil distribution, controller mode and target market usage instructions.

K85 red and near-infrared lamp bead configuration

K85 is equipped with a total of 36 photon lamp beads, of which 22 are 660 nm visible red light beads and the other 14 are 850 nm invisible near-infrared lamp beads. The two bands have different visibility and light source parameters and should not be described as functionally equivalent.

850 nanometer near-infrared lamp beads cannot be judged by the naked eye whether they are lit or not during operation. Product inspection and batch quality inspection need to be completed according to lamp bead parameters, controller status and corresponding detection methods.

Product Specifications

  • Product model: K85
  • Product Type: Tourmaline PEMF Red Light Near Infrared Heating Mini Pad
  • Product Dimensions: Approximately 19 × 34 inches
  • Metric dimensions: approx. 47 × 85 cm
  • Product Weight: Approx. 10 lbs., Approx. 4.5 kg
  • Internal material: Nano tourmaline microceramic balls
  • PEMF coil: 2
  • PEMF Frequency: 3 to 64 Hz
  • Total number of photon lamp beads: 36
  • 660 nanometer red light beads: 22
  • 850 nanometer near-infrared lamp beads: 14 pcs
  • Power rating: 100 watts
  • Voltage specifications: 110 to 120 volts or 220 to 240 volts
  • Temperature range: 30 to 70 degrees Celsius
  • Fahrenheit temperature range: 85 to 159 degrees Fahrenheit
  • Timing range: 1 to 12 hours
  • Storage configuration: equipped with portable storage bag

Applicable scenarios and usage

K85 can be placed flat on the bed, sofa, yoga mat or nursing bed for support and warming experience on the back, waist or lower legs. The compact size is also suitable for family lounging, reading, meditation, office breaks and relaxing before bed.

can be used for the first time from a lower temperature and a shorter time, ensuring that the pad is placed flat to avoid sharp folds or blocking the controller. Users should adjust temperature and run time based on personal tolerance.

If you want to see more tourmaline products, you can visit tourmaline pad product category . For bulk purchasing or supplier cooperation, you can view the wholesale supplier page.

Wholesale, supply and OEM, ODM customization

K85 is suitable for tourmaline pad manufacturers, health care product suppliers, wholesalers, distributors, SPA brands and wellness project procurement. Bulk items can be confirmed around tourmaline material, pad body size, surface fabric, controller, voltage, plug, packaging and instruction language.

OEM, ODM and private label projects can customize brand logo, surface fabric, controller interface, storage bag and outer packaging. Factory direct supply projects can also configure corresponding voltages, plugs and instructions according to the target market, and establish sample confirmation, batch quality inspection and delivery processes.

Precautions for use

K85 is a health care and relaxation product and should not be used as a substitute for medical diagnosis, medication or regular treatment. People who have pacemakers or other implantable electronic devices, are pregnant, are sensitive to heat, have sensory impairments, or are receiving important medical treatment should consult a medical professional before use.

The pad body should be kept flat during use, and do not fold sharply or place heavy objects on the pad body. Turn off the power and disconnect the plug before cleaning to prevent moisture from entering the pad body, controller and interface. If abnormal fever, circuit damage, odor or other obvious discomfort occurs, you should stop using it immediately.